Basic Info.
Output Type
AC Three Phase
Certification
CE, TLC, ISO, CCC
Name
Energy Saving 100kw, 200kw500kw Biogas Generator
After-Sales Service
Overseas Service Center Available
Color
Client′s Requirements
Transport Package
20gp, 40gp, 40hq
Specification
100kw, 200kw, 500kw, 1mw
Product Description
- Energy saving 100kw,200kw500kw biogas generator,1MW biomass electric generator price
Project Name: 300KW Low Speed Biomass Power Generating PlantProject Contents: By using raw materials like municipal solid waste (MSW), wood chips, crop straws, saw dust, coconut shells, rice husks, palm kernel shell, coal powder and used tire, we can get biomass through gasification process. After filtering, de-hydrating, tar-removing and other necessary treatments, the biomass will be delivered to gas tank, and finally to gas engine for power generating. And at the same time, CHP System (heat collect boiler) can make heat recovery from exhaust gas to get hot water or steam, which can realize comprehensive and high-efficiency utilization of the power plant.- TECHNICAL FEATURES OF POWER BIOMASS ENGINES
-
- Unique Advantages of Power Low Speed Biomass Engines
- Power Biomass Generator Set is driven by low speed engine of 300 series, coupled with Siemens alternator, power ranging from 300kw up to 500kw. The applicable fuel can be biomass including biomass gas, wood gas, Straw Gas and coal gas etc. Our biomass engines can work at reliable performance, easy for maintenance and much longer life-span Our generators enjoy hot markets in overseas markets including Italy, Russia, Ukraine, Latvia, Croatia, Serbia, South Africa, Tanzania, Philippines, Thailand, Indonesia, Korea and Japan etc.
- Based on Biomass as fuel, the reasons why we suggest our 300 series low speed engines.
Biomass is far different with methane base gas (natural gas, biogas and Coal mine gas etc). Biomass is much more tricky, it is low in heat value, high in tar content and unstable in gas quality (TAR always raise problems of pipeline-blocking, cylinder-pollution and spark plug-jamming etc). So, there are few engines can be fired by biomass properly. However, our 300 series low speed engines can work at biomass smoothly. The key reasons are that our 300 series engines have unique and remarkable features & advantages as follows: - Cylinders Structure in Line & Upright and Concise Layout, which means easy and low cost in maintenance;
- Large cylinder (Bore × Stroke=300 × 380mm), Long Stroke, Low Speed and Big displacement 215L, which means big reserve power capacity and constant power output.
- Low Engine Speed at 500 or 600RPM, which means high reliability for continuous operation, sufficient combustion, low exhaust gas temperature and high heat efficiency; Low Engine Speed can reduce dramatically wearing of engine parts, prolong life span.
- Naturally Aspirated (no turbocharger and Intercooler), which means low failure rate and minimal downtime (Tar in biomass always block and damage turbocharger and intercooler);
-
- Internal Mixing System (for high hydrogen gas). Gas and air intake separately, then mixed in combustion room, which means no risk of backfire and knocking.
- Strong Treatment and Resistance Ability against TAR, which means long term trouble free operation.
- Low Noise, low engine speed means lower noise, the noise level ≤ 100dB in working condition. By using silencer, the noise level can be ≤ 80dB.
- CHP System (Combined Heat and Power), making heat recovery from exhaust gas to get hot water or steam, which can realize comprehensive and high-efficiency utilization of the power plant.
- Long Overhaul Time of 60000 hours and lifecycle of 20-25 years, which secure constant economic benefits of your power plant.
-
- Requirements for lubrication oil and cooling water:
- The biomass genset is equipped with complete lubrication oil system. Lubrication oil consumption is less than 1.0 g/kW.h; Lubrication oil specification: 40CD or 15W40CD (GB/T11123-1989) or SAE40;
Engine's high & low temperature cycle adopts softened water. Cooling water should be clean water with slightly alkaline, shall not contain corrosive substances, such as chloride, sulfate, or acid, etc. Detailed requirements are as follows:
Total Hardness (CaCO3) ≤100ppm; Chloride-ion Content<150mg/L; PH Value 7~8.5
- Biomass Quality Requirements
-
- Before entering into engine, the biomass should be appropriate filtering, gas-liquid separation and pressure regulation. If the temperature is too high, it should be through cooling treatment, and make sure there is no liquid content in the gas.
- Gas temperature≤40°C, Gas pressure 2.5~10kpa, Pressure change rate≤1kPa/min, Tar content≤20mg/Nm3,
- H2S content≤50mg/Nm3, Impurities particle size≤5μm, Moisture content≤20 mg/Nm3, Impurity content≤30mg/Nm3, Heat value≥4MJ/Nm3.
- Ambient Environment requirement
- The genset can run steadily and continuously at following environmental conditions: ambient temperature: -20°C~+40°C, relative humidity<90% (20°C), height above sea level≤2500m.
In standard conditions (atmospheric pressure 100kPa, environment temperature: 25°C, air relative humidity 30%), the genset can work at full load of output power 300kW.
- Brief introduction of genset main system
-
- Gas system
- The gas system is the equipments from biomass-storage tank to biomass engine, like air intake duct, pipe, valve, flame arrester, control equipment etc.
Clean biomass are delivered from biomass-storage tank to biomass main pipe, and then to branch pipe, butterfly valve, and finally biomass engine. For the purpose to ensure safe running of biomass genset, butterfly valves, emergency shut-off solenoid valve, dry-type fire arrestor are installed in biomass transmission pipeline.
Following is biomass transmission route: biomass storage tank→main pipe→fire arrestor→butterfly valves→branch pipe→butterfly valves→biomass engine. In some projects, in order to fully guarantee the cleanness of biomass, basket-type filter will be installed. - Exhaust system
- The exhaust system includes bellows expansion joint, exhaust pipe, muffler and muffler support. If with CHP or waste heat recovery system, for the purpose to avoid damage to muffler and heat recovery system by high exhaust pressure, explosion-proof valve will be installed on the exhaust pipe.
Following is the working order of the exhaust system: Gas generator set exhaust vent →expansion joint→ pipeline→explosion-proof valve (optional)→ CHP/waste heat recovery unit (optional) → pipe→ muffler → the air atmosphere.
Engine exhaust temperature is about 550°C, so the exhaust system components are made by high-temperature-resistant material. The exhaust pipe is hanged on the roof by hoop with hoisting wire rope and the muffler is installed on the muffler bracket.
The exhaust pipe sizes is DN300, and the engine exhaust pipe in the generator room shall be wrapped with two layers' insulations: the inner layer by aluminum silicate ceramic tube shell with thickness at 50mm, and the outer layer by galvanized iron with thickness at 0.4mm. After insulation, the surface temperature should not be over 60°C.
- Cooling System
- Regarding to cooling methods, gas engine is with open cooling as standard (closed water cooling of radiator is optional). In order to improve the corrosion-resistance performance of cylinder block and cylinder jacket, increase thermal efficiency, the engine cylinder and cylinder-head exhaust-pipes are cooled by fresh water. Lubrication oil cooler and fresh water coolers are cooled by water from cooling tower.
High temperature cycle (called inner cycle) is mainly to cool parts like the cylinder block, cylinder jacket, cylinder head, etc. Low temperature cycle (called outer cycle) is mainly through heat-exchanger to cool the lubrication oil and cooling water in the high temperature cycle; the water in the low temperature cycle is cooled by cooling tower, its water temperature is about 20-30°C. Cooling water for low temperature cycle is 40m3/h, through the heat changer; temperature is increased by 15°C. The inner cycle used softened water; the consumption rate for one genset is about 5kg per day.
As shown in the following drawing, low temperature water flow-line: cooling tower→fresh water pump→lub.oil cooler→fresh water cooler→cooling tower.
High temperature flow-line: fresh water pump→water inlet manifold→gas engine→heat-resistant water chamber of exhaust pipelines→fresh water cooler→fresh water pump.
ITEM. | DESCRIPTION |
Genset Model | LH300GFJ |
Rated Power | 300kW |
Rated Voltage | 400V (Low Voltage of 415/440V/480V/690 and high voltage of 6.3kv,10.5kv are available) |
Rated Current | 541A |
Rated Frequency | 50HZ (60HZ is available) |
Power Factor COSΦ | 0.8 (lag) |
Excitation Type | Brushless, Self-Excitation |
Voltage Stationary Regulation Ratio (100%) | ±2.5 |
Instant Voltage Regulation Ratio (%) | ±15 |
Voltage Stable Time (%) | ≤1.5s |
Voltage Fluctuation Ratio (%) | ≤0.5 |
Frequency Steady-state Regulation Ratio (%) | ≤5 (0~5 adjustable) |
Instant Frequency Regulation Ratio (%) | ±10 |
Frequency Stable Time | ≤7s |
Phases and Connecting Methods | 3 phases 4 wires |
Biomass Engine Model | 6300D/J |
Engine Style | Water Cooled, Four stroke, spark plug ignition, naturally aspiration. |
Cooling System | Heat Exchanger+Cooling Tower (Table Type Radiator is optional) |
Cylinder No. and Arrangement | 6 in Line |
Cylinder bore | 300mm |
Stroke | 380mm |
Compression Ratio | 9:1 |
Displacement | 161L |
Rated Rotation Speed | 500RPM |
Rated Engine Power | 330kW |
Rated Load Thermal Consumption | ≤12 MJ/kW·h |
Oil Consumption | ≤ 1.0 g/kW.h |
Start Method | Compressed Air Start |
Inlet Gas Temperature | ≤40°C |
Each Cylinder Exhaust-gas Temperature | ≤550°C |
Noise | 100dB (≤ 70dB by Silencer) |
Gas pressure Requirement | ≥2.5kPa |
Gas inlet temperature (ºC) | ≤40 |
Overhaul Time | Around 60000 Hours |
Life Span | 20~25 years |
Alternator | Siemens 1FC6 Series or Equal (Self Excited, Brushless, AVR, IP23, 50/60HZ, Both Low Voltage and High Voltage are available) |
Genset Overall Size | 5800×1600×2900 (LxWxH, mm) |
Genset Gross Weight | 18000kg |
Address:
Room 325, Building 1, No. 55 Lianhua Street, High-Tech Zone, Zhengzhou, Henan, China
Business Type:
Manufacturer/Factory
Business Range:
Industrial Equipment & Components, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy, Transportation
Management System Certification:
ISO 9001, ISO 9000, ISO 14001, OHSAS/ OHSMS 18001
Company Introduction:
Henan Dianyan New Energy Technology Co., Ltd. is a high-tech enterprise specializing in green energy, energy-saving technology development and related equipment manufacturing. The manufacturing plant is located at No. 19, Longjiang Road, Shangjie District, Zhengzhou City, covering an area of 20000.
The company is developed on the basis of the former Kunming Dianyan New Energy Research Institute. After years of technical research, the new generation high-temperature pyrolysis technology of biomass gasifier system and purification system. Renewable energy utilization provides the perfect solution for waste recycling and improving environmental pollution caused by improper waste disposal. This series of equipment has reasonable design, advanced technology, excellent quality, and has the characteristics of environmental protection and wide application of raw materials.
Our company has made unremitting efforts and continuous improvement of management, and has a good competitive advantage in domestic and foreign. The company adheres to the business philosophy of "excellent technology, reliable products, and quality as life". It is committed to the R&D, design and construction of green energy projects, providing customers with reliable and comprehensive solutions for renewable resources, creating value for the society. We operate under ISO 9001-2015, ISO14001-2015, OHSAS18001-2007 certification which positions us as a company with high standards of quality, delivery times and excellent service levels.
Our products including: Biomass gasifier, biomass-gas clean &purify system, biomass gasification and power generation plant, biomass burners, coal gasifier, coal gasification and gas clean system, perlite and vermiculite expansion furnace and producing line, shredder, conveyor, dryer system, and auxiliary equipments of these systems.